临沂冷水机 TCL-10HP 风冷箱式|注塑模具降温
临沂冷水机 TCL-10HP
Industrial Chiller TCL-10HP for Linyi
临沂冷水机 TCL-10HP(Industrial Chiller TCL-10HP):风冷箱式一体机,出水温度 7~15℃,面向鲁南及周边地区供货,含冷量计算、管路配套建议、发货与上门调试。
Industrial Chiller TCL-10HP for Linyi: an air-cooled unit with outlet water at 7-15 C, supplied to southern Shandong and nearby cities, with cooling-load sizing, piping advice, delivery and on-site commissioning.
设备说明 / Equipment Overview
10HP 风冷箱式,冷凝靠翅片加轴流风机散热,不用配冷却塔;占地小,接管只需进水管、回水管与补水三处,适合车间没有塔位、又不想铺冷却水管的场合。
A 10HP air-cooled box unit rejecting heat through finned coils and axial fans, no tower needed. Three connections only: supply, return and make-up.
结构与控制 / Structure & Control
压缩机与翅片式冷凝器上下分层布置,冷凝风从侧面进、顶面出;水箱与管道泵装在机内,电控箱独立放在面板侧,进出水口为 1 英寸内螺纹,配可视压力表与补水浮球。
Compressor and finned condenser are stacked with side intake and top discharge air. Tank and inline pump sit inside the frame, the control box is at the panel side, and ports are 1 inch female thread.
运行与精度 / Performance & Accuracy
按回水温度控制压缩机启停,冷启动带延时保护避免短循环;水温稳定后进出水温差收敛在 3~5℃,模具冷却时间比直接用塔水明显缩短,薄壁件的外观与尺寸更稳。
Compressor cycling follows return-water temperature with a start delay to prevent short cycling. Once stable, the supply-return difference settles at 3-5 C, mold cooling time shortens noticeably against tower water, and thin-wall parts hold appearance and dimensions better.
操作与维护 / Operation & Maintenance
每月吹扫冷凝器翅片(粉尘大的车间半月一次),每季度校核温度探头与压力表,长期停机排空水箱;翅片倒伏或积灰厚时冷量下降快,先清理再考虑加匹数。
Blow down the condenser fins monthly, every two weeks in dusty shops; verify probe and gauges quarterly; drain the tank for long shutdowns. Collapsed or clogged fins cut capacity quickly, so clean first before considering a larger unit.
参数速览 / Specifications
型号 TCL-10HP|制冷量 约 9 kW|出水温度 7~15℃|控制精度 ±1℃|循环流量 约 30 L/min|水泵压力 0.15~0.2 MPa
Model TCL-10HP | Capacity approx. 9 kW | Outlet 7-15 C | Control accuracy plus or minus 1 C | Flow approx. 30 L/min | Pump pressure 0.15-0.2 MPa
应用场景 / Applications
注塑模具冷却、挤出与吹膜辊筒降温、片材与型材线定型、小型检测台恒温循环。
Mold cooling on injection machines, roller cooling on extrusion and blown film lines, sheet and profile calibration, and constant-temperature loops on small test benches.
鲁南地区配套 / Local Supply in southern Shandong
临沂及鲁南一带板材、管材、塑料编织与再生料造粒的机台密度大,机台新旧混杂、单机功率跨度大,一机配多模是常态。当地看重短交期与现场响应,水泵、温控器、风机电容等常用件按常规库存备货,就近工程师处理水温不稳、高压报警一类问题。
Linyi and nearby run dense clusters of board, pipe, woven-bag and reclaim pelletising lines, with machines of mixed age and power, so one chiller feeding several molds is normal. Short lead times and on-site response matter, so pumps, controllers and fan capacitors are kept in stock and a local engineer handles temperature drift and high-pressure alarms.
选型与交付流程 / Sizing & Delivery
给出制品单重、成型周期、机台吨位与料种后,按公式折算冷量并给出机台—冷量匹配表;签约后按交期发运,到场接管、排空、调试并记录进出水温差与压力,随机附操作手册与备件清单。
Send part weight, cycle time, clamp tonnage and material, and we return a cooling-load figure with a machine-to-capacity table. After order we ship on the agreed date, connect and vent the loop on site, commission it with recorded supply-return difference and pressure, and hand over the manual and spare list.
常见问题 / FAQ
Q:冷量怎么算?
Q: How is the cooling capacity calculated?
A:按 Q=W×C×ΔT×S 估算:W 是每小时用料重量,C 是料种比热(PP 0.48、PE 0.55、ABS 0.40、PC 0.30 kcal/kg·℃),ΔT 取熔胶与脱模温度之差、常用 200℃,S 取 1.35~2.0;算出 kcal/h 后按 1kW=860 kcal/h 折算,再往上取一档机型。
Estimate with Q = W x C x dT x S: W is material throughput per hour, C is specific heat (PP 0.48, PE 0.55, ABS 0.40, PC 0.30 kcal/kg·C), dT is melt minus ejection temperature (200 C is typical), S is 1.35-2.0. Convert kcal/h to kW at 1 kW = 860 kcal/h, then take the next size up.
Q:风冷和水冷怎么选?
Q: Air-cooled or water-cooled?
A:有冷却塔、三班连续生产、电价偏高时用水冷,冷凝温度稳定、能耗低;缺水或没位置放塔时用风冷,接三根管就能开,夏季环境温度高于 35℃ 时冷量会掉 10%~15%,选型留余量。